Vista de pagina 0
TC6054OI Rev. AA 5/11 ©2010 Avery Dennison Corp. All rights reserved.
6054 Network
Control Module
6055 Docking Modules
OPERATING INSTRUCTIONS
Use these Operating Instructions to assemble and use
the 6054 Network Control Module and the 6055 Docking
Module.
The 6054 Network Control Module controls one to four
6055 Docking Modules, which provides Pathfinder® 6057
printer charging and Ethernet communication capability
The 6054 Network Control Module and the 6055 Docking
Module can only be used with printers that contain the
approved battery as listed in the printer documentation.
Refer to the Operator’s Handbook for additional important
battery safety information.
Follow the operating and storage limit specifications
listed at the end of these instructions. Otherwise, the
battery may permanently lose its charge capacity.
Note: You must charge the printer before using it.
Vista de pagina 0
1 2 3 4 5 6 7 8

Indice de contenidos

Pagina 1 - OPERATING INSTRUCTIONS

TC6054OI Rev. AA 5/11 ©2010 Avery Dennison Corp. All rights reserved. 6054 Network Control Module6055 Docking Modules OPERATING INSTRU

Pagina 2

2 Assembling the Network Control Module 1. Turn over the 6055 Docking Module and 6054 Network Control Module. 2. Using a Philips screwdriver, remove

Pagina 3

3 4. Loosen the two screws on the 6054 Network Control Module and slide the 6054 Network Control Module onto the Docking Module’s connector plate. T

Pagina 4 - Cable goes here

4 Setting up the Network Control Module 1. Plug the supplied power cable into the Network Control Module. 2. Plug the other end of the cable into a

Pagina 5 - Charging the Battery

5 Reading the Ethernet LEDs When the communication port is connected, two LEDs indicate the following: LED ON OFF Blinking Yellow Full Duplex Mode

Pagina 6 - Troubleshooting

6 The green power LED on the 6054 Network Control Module turns on when there is power to it. Charging time can take up to three hours. It takes appro

Pagina 7 - Specifications

7 Specifications Operating Limits: Temperature 32°F to 104°F (0°C to 40°C) Humidity 5% to 90% non-condensing Storage Limits: Temperature -40°F to 1