If there is a text field you don’t want to use, enter that field
number and a semi-colon with no print data.
Example
This example contains data to print the label shown below.
You’ll find the data stream for this format in the section "Format
Data."
{B1,0012,1,01,1,0,C;PTEST
T00;TEST FORMAT1
T01;S/N 97464B
T02;$12.34
B00;0012345678905
}
This batch has the following attributes:
This batch prints the phrase "TEST FORMAT 1" in text
field T00.
This batch prints the phrase "S/N 97464B" in text field
T01.
This batch prints the phrase "$12.34" in text field T02.
This batch prints the number "0012345678905" in bar
code field B00.
Syntax Checklist
Make sure these batch data records are preceded by a
batch header record.
Make sure the first parameter (field number) matches
the field number in your format.
Message Structures
4. Message Structures