Scanning Functions 4-9
Postamble
Description
Sets the Postamble, which is the data to be sent after each scanned bar
code. The Postamble can be up to twenty user-defined characters.
Syntax
Postamble
Parameters
Postamble up to 20 characters
Default: Empty
Return Values
None
Example
<SCRIPT src="./jsUltra.js"></SCRIPT>
<SCRIPT type="text/javascript">
GENERAL.Postamble = "]"; //Adds [ at end of all scanned data
SCANNER.CommitConfigChanges();
//Save Changes to the Scanner Configuration
</SCRIPT>
<BODY>
<OBJECT id=”GENERAL” style="LEFT: 0px; WIDTH: 0px; TOP: 0px;
HEIGHT: 0px"
classid=clsid:B1EED6A7-2259-442D-B273-71EBE93C8338>
</OBJECT> //Instantiate Class
<OBJECT id=”SCANNER” style="LEFT: 0px; WIDTH: 0px; TOP: 0px;
HEIGHT: 0px"
classid=clsid: AD3C761C-4BCC-403D-A68D-128ED702A417>
</OBJECT> //Instantiate Class
</BODY>