Avery-dennison Platinum 6039 JavaScript Manual de usuario Pagina 68

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 94
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 67
4-30 Programmer’s Manual
Field Description
XmitUPCAPre
Specifies how to transmit UPCA Preamble characters.
Values are:
1 = XUP_NONE Do not transmit.
2 = XUP_SYSCHAR Transmit system character.
3 = XUP_SYSCOUNT Transmit system character and
country code.
Default: XUP_SYSCHAR
XmitUPCEPre
Specifies how to transmit UPCE Preamble characters.
Values are:
1 = XUP_NONE Do not transmit.
2 = XUP_SYSCHAR Transmit system character.
3 = XUP_SYSCOUNT Transmit system character and
country code.
Default: XUP_SYSCHAR
XmitUPCE1Pre
Specifies how to transmit UPCE1 Preamble characters.
Values are:
1 = XUP_NONE Do not transmit.
2 = XUP_SYSCHAR Transmit system character.
3 = XUP_SYSCOUNT Transmit system character
and country code.
Default: XUP_SYSCHAR
XlateEtoA
Translates a UPCE bar codes to a UPCA bar code.
Default: false
XlateE1toA
Translates a UPCE1 bar codes to a UPCA bar code.
Default: false
EANZeroExtend
Adds five leading zeros to scanned EAN8 bar codes to
make them compatible with EAN13 bar codes.
Default: false
Xlate8TO13
Translates an EAN8 bar code to an EAN13 bar code.
Default: false
Security
Sets the scan security level, which is how many times
to scan the same bar code to determine a successful
read. Choose the minimum-security level needed.
Values are
0 Use when most scans are successful.
1 Use when the unsuccessful scans are related
to characters 1, 2, 7, and 8.
2 Use when the unsuccessful scans are not limited
to characters 1, 2, 7, and 8.
3 Choose 4 if unsuccessful scans still occur at
level 2. Default: 0
Vista de pagina 67
1 2 ... 63 64 65 66 67 68 69 70 71 72 73 ... 93 94

Comentarios a estos manuales

Sin comentarios